Mezzanine structure
Specifications
3.1 Railings
3.1.1 Railing shall be a minimum of 1-1/2” X 11 ga. square tube.
3.1.2 Kickplate shall be a minimum of 4” high X 14 ga. steel.
3.1.3 Standard handrail designs include OSHA, IBC Factory Use Group, IBC Merchantile Use Group, and BOCA.
3.2 Columns
3.2.1 Mezzanines shall be designed so that column spacing shall meet field conditions and requirements of customers.
3.2.2 Column size shall be a standard of 5” X 5” X 3/16” tubular steel.
3.2.3 Base plates shall be a standard of 12” X 12” X 5/8” and anchored with a minimum of four (4) 1⁄2” diameter anchor bolts.
3.3 Structural Steel, Support Members and Bar Joists
3.3.1 All field connections shall be bolted.
3.4 Stairs
3.4.1 Stairs shall be of a bolt together construction
3.4.2 Standard designs include OSHA, IBC Factory Use Group, IBC Merchantile Use Group, and BOCA